Cemtek Instruments 8000 SCR NOx Analyzer
Superior performance on all types of applications.

SCR Inlet NOx monitoring for NH3 control.

Outstanding performance on coal fired boilers, gas & oil fired boilers, gas turbines, IC Engines, diesel fired units and all other NOx monitoring applications.

Complete System ready to install includes analyzer, probe & controls.

Responds in seconds and can be used for loop back control.

Low range of 0-10ppm high range up to 10,000ppm.

Low pressure dilution technology. Clean dry diluted sample is measured.

No sample conditioning required.



Product Description



Cemtek's Model 8000 SCR NOx and O2 Monitor has been designed specifically to meet the challenging requirements for monitoring the inlet and outlets of selective catalytic reduction systems on coal fired combustion sources. This can be used for NOx control, NH3 injection control and emissions control.

 

Designed around a close coupled low flow - low dilution probe, the Model 8000 NOx analyzer integrates all of the major components necessary to simultaneously measure nitric oxide and oxygen concentrations without the need for costly heated sample lines or separate instruments.

 

Utilizing a  NOx chemiluminescent photo-diode detector,  no photomultiplier tubes, high voltage supply or lamps to fail provides long turn reliability. Optimization of the NOx reaction cell eliminates the need for temperature, flow and pressure compensation. Zero drift is practically nonexistent. An ozone generator that produces ultra clean discharge is also a key feature of the Model 8000 NOx analyzer.

 

A very compact zirconium oxide sensor with heater and detector cell complete on a monolithic ceramic base requires only 10W of power and is insensitive to ambient temperature swings. Our sensor uses a proprietary two-stage cell that results in an inherently linear output with excellent sensitivity and stability across its range.This results in very low zero drift and no low level calibration gas required.

 

The Model 8000 NOx analyzer can be mounted directly on a duct port both before and after an SCR to measure real time NOx and O2 or to provide trim control of the ammonia injection process. An air condition package for applications is where high ambient temperatures are encountered at the SCR inlet. The enclosure/probe is mounted by a 4" ANSI flange. Simple probe design allows for easy removal and maintenance of filters without the need of removing any other component. 

 

 

NOx, NOx control, Chemiluminescent NOx analyzer, NO control, SCR, NOx control, NOx process control and monitoring.






 Product Specifications

Measurement Technology NOx Chumiluminescence O2 Zirconium Oxide Cell
Range (FS Adjustable): Solid State Detection:
5 to 1000PPM
5-25%
Linearity (FS): <2.0% <1.0%
Zero Calibration Drift: +/- 0.2% PPM +/- 0.1 PPM
Zero Noise: <0.02 PPM <0.02%
Span Calibration Drift: +/-2.0% +/-0.1%
Span Noise: <0.25% of reading <0.02%
Interference (sum of all): 
< 10.0% measured value  < 1.0%
Response Time:   < 10 seconds at T95 <10 seconds at T95




System Requirements:

Power: 115VAC, 150 Watts @ 2 A            

Air: 2 CFM @ 60 PSI

Weight: 50 lbs. approximately

Size Dimensions: 22” x 16” x 12” NEMA 4 Enclosure

Outputs: Isolated 4-20mA per gas measured